Project Name: |
Newhaven Business Centre | ||
Size of Installation: |
13.6 kWp | ||
Type of Installation: |
New build pitched on-roof system | ||
Client: |
Lewes District Council | ||
Equipment: |
Module – 84 x Sharp ND-162E1 framed modules Inverter – 3 x Fronius IG40 units Mounting system – UniRac SolarMount, with UniStrut primary rails Public Display – RiCo GA1000 |
||
Predicted Generation: |
10000 kWh per year | ||
Project SummaryA large single PV array was installed on the roof of a new business centre in Newhaven, East Sussex, designed to offset 10% of the building’s carbon emissions. A bespoke fixing system to the standing seam roof was designed using a twin-rail system. |
|||
Technical InformationThe system comprises of 84 high efficiency polycrystalline Sharp PV modules, with a Fronius IG40 inverter on each of three phases converting the output to grid-standard AC electricity. A twin-rail mounting system was designed to mount the modules to the standing seam roof without compromising its integrity. A public display board with live LED readouts of system performance and a customised graphic was fitted in the reception area. |
|||
Social, Economic and Environmental BenefitsThe system saves approximately 6.2 tonnes of CO2 emissions every year, enabling the building to meet its target of saving 10% of the total emissions. When the building is not in use, the modules continue to generate power, creating additional revenue for the owners by through resale of energy to the national grid. |
|||
|
|
|||
OS Reference: |
TQ 445 016 | ||
Type: |
PV Wind Hydro |
||